Part: 118-70-74-651
Category: Optoelectronics -> Photosensors -> Photodiodes -> Avalanche Photodiodes
Description: Non-cooled Oem Module
Company: Advanced Photonix
Datasheet: Download 118-70-74-651 datasheet File size : 229 kB
Request For quote: Find where to buy 118-70-74-651
Datasheet text preview:
Non-Cooled OEM Modules
Electro-Optical Characteristics
All specifications apply when APD is at 23ºC with a gain of 200 and a load resistance of 50 ohms.
Part Number
APD Diameter (mm)
APD Spectral Enhancement UV Blue Red/IR UV Blue Red/IR UV Blue Red/IR
118-70-73-651 118-70-74-651 118-70-72-651 197-70-73-651 197-70-74-651 197-70-72-651 394-70-73-651 394-70-74-651 394-70-72-651
3
5
10
NEP ensitivity @ 1 MHz Typical* Typical* (105 V/W) (pW/ Hz) 3.4 0.16 6.7 0.08 9.3 0.06 3.4 0.22 6.7 0.12 9.3 0.085 3.4 0.55 6.7 0.28 9.3 0.2
Frequency High Cutoff Typ Min (MHz) (MHz) 14 12
14
12
11
10
Feedback Resistance (k ) 20±1%
Output Output Linear Offset Impedance Output Typ Max Swing (mV) (mV) () (V) ±1 ±5 50 +1
Current Consumption Output Stability +12V±1V Supply -12V±1V Supply Typical Typ Max Typ Max (%/ºC) (mA) (mA) (mA) (mA) 0.5 120 220 30 50
S Absolute Maximum Ratings Supply APD Active Continuous Incident APD Gain @ Ambient Storage Light Intensity Voltage Diameter 23ºC Operating Temp. APD gain =200 =675nm Temp. (ºC) =675nm (µW) (V) (mm) (ºC) 0.75 3 1.0 ±13 5 250 0 to +40 -40 to +70 2.0 10
HV bias/APD gain control realized by potentiometer located on backside of the module or remote 0 to +5V analog programming configured by jumper located on backside of the module. Remote HV control ratio: 404 V per 1V (typical). HV monitor ratio: 404 V per 1V (typical). Temperature monitor output is 10mV/ºK. (See National Semiconductor data sheet for LM335 temperature sensor.) Recommended load on the amplifier output is from 50 ohms to 1 Mohm. Modules can be modified or customized by Advanced Photonix to meet individual customer requirements. Operating beyond these limits may cause permanent damage to the device. * Sensitivity and NEP for UV, Blue and Red/IR specified at wavelengths of 350nm, 500nm and 750nm, respectively.
14
w w w. a d v a n c e d p h o t o n i x . c o m
Typical Performance Graphs
Blue Red/IR 5 mm UV 3 mm
10 mm
Mechanical Dimensions
Non-Cooled OEM Modules
Electric Wiring Table Wire Color
Red Green Black Orange Blue Violet
Item
+12V GND -12V HV Monitor External Bias Adjust Input Temperature Monitor
(805) 987-0146 · Fax (805) 484-9935
15
Others parts begin by 11
11-1 11-2 11-3
|
|
|