4 X 4 X 2 CROSSPOINT SWITCHES WITH CONTROL MEMORY
. . . . . . . .
LOW ON RESISTANCE 75 TYP AT VDD = 12 V "BUILT-IN" LATCHED INPUTS LARGE ANALOG SIGNAL CAPACITY ± VDD/2 10 MHz SWITCH BANDWITH MATCHED SWITCH CHARACTERISTICS RON = 8 TYP, AT VDD = 12 V HIGH LINEARITY 0.25 % DISTORTION TYP, AT f = 1 kHz, VIN = 5 V, VDD - VSS = 10 V AND RI = 1 STANDARD CMOS NOISE IMMUNITY
D ESC R I PT I O N The M 22101 and M22102 crosspoint switches consist of 4 x 4 x 2 arrays of c rosspoints (transmission gates), 4-line to 16-line decoders, and 16 latch circuits. Any one of the sixteen crosspoint pairs can be selected by applying the appropriate four-line address and any number of crosspoint pairs can be ON simultaneously. Corresponding crosspoints in each array are turned on and OFF simultaneously, also. In the M22101, the selected crosspoint pair can be turned on or off by applying a logical ONE or ZERO, respectively, to the data input, and applying a ONE to the strobe input. When the device is "power-up", the state of the 16 switches is indeterminate. P I N CO NNE C TI O N S
Therefore all switches must be turned off by putting the strobe hight, data-in-low, and the addressing all switches in succession. The selected pair of crosspoints in the M22102 is turned on by applying a logical ONE to the Ka (set) input while a logical ZERO is on the Kb (reset) input, and turned off by applying a logical ONE to the Kb input while a logical ZERO is on the Ka input. In this respect the control latches of the M22102 are similar to SET/RESET flip-flops. They differ, however, in that the simultaneous application of ONEs to the Ka and Kb inputs turns off (resets) all crosspoints. All crosspoints in both devices must be turned off as VDD is applied.
B1 (Plastic Package)
F1 (Ceramic Package)
O RD E R CO D E S : M 22X X X B 1 M 22X X X F 1
September 1988
1/8
M 22 10 1 / M 2 210 2
ABSOLUTE M A XI M U M R A T I N G
Symbol VDD Vi II Ptot Parameter Supply Voltage: Ceramic Type Plastic Type Input Voltage DC Input Current (any one input) Total Power Dissipation (per package) Dissipation per Output Transistor for Top = Full Package Temperature Range Operating Temperature: Ceramic Type Plastic Type Storage Temperature Value -0.5 to +20 -0.5 to +18 -0.5 to VDD + 0.5 ± 10 200 100 -55 to +125 -40 to +85 -65 to +150 Unit V V V mA mW mW
o o o
Top Tstg
C C C
Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability.
R EC O M M EN D ED O PE R A T I N G C O N D I T I O N S
Symbol VDD VI Top Parameter Supply Voltage: Ceramic Type Plastic Type Input Voltage Operating Temperature: Ceramic Type Plastic Type Value 3 to 18 3 to 15 0 to VDD -55 to +125 -40 to +85 Unit V V V
o o
C C
C O N T R O L T R U T H T A B L E F O R M 221 0 1
Function Switch-on Switch-off No Change A 1 1 X Address B C 1 1 X 1 1 X D 1 1 X Strobe 1 1 0 Data 1 0 X Select (X4 Y4) & (X4' Y4') (X4 Y4) & (X4' Y4') XXXX
Note: 1 = High, 0 = Low, X = Don't Care
C O N T R O L T R U T H T A B L E F O R M 221 0 2
Function Switch-on Switch-off All Switch-off No Change A 1 1 X X Address B C 1 1 X X 1 1 X X D 1 1 X X Strobe 1 0 1 0 Data 0 1 1 0 Select (X4 Y4) & (X4' Y4') (X4 Y4) & (X4' Y4') All XXXX
Note: 1 = High, 0 = Low, X = Don't Care
2/8
M 22 1 01 / M 2 21 02
D EC O D ER T R U T H T A B L E
Address A 0 1 0 1 0 1 0 1 B 0 0 1 1 0 0 1 1 C 0 0 0 0 1 1 1 1 D 0 0 0 0 0 0 0 0 X1 Y1 X2 Y1 X3 Y1 X4 Y1 X1 Y2 X2 Y2 X3 Y2 X4 Y2 Select X1' Y1' X2' Y1' X3' Y1' X4' Y1' X1' Y2' X2' Y2' X3' Y2' X4' Y2' Address A 0 1 0 1 0 1 0 1 B 0 0 1 1 0 0 1 1 C 0 0 0 0 1 1 1 1 D 1 1 1 1 1 1 1 1 X1 Y3 X2 Y3 X3 Y3 X4 Y3 X1 Y4 X2 Y4 X3 Y4 X4 Y4 Select X1' Y3' X2' Y3' X3' Y3' X4' Y3' X1' Y4' X2' Y4' X3' Y4' X4' Y4'
FUNCTIONAL A N D B L O C K D I A G R A M