Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: DBA100UA40

Category:
 Discrete
   -> Diodes & Rectifiers
     -> Modules
             -> Soft Recovery Diodes

Description:

Company: SanRex Corporation

Datasheet: Download DBA100UA40 datasheet     File size : 88 kB

Request For quote: Find where to buy DBA100UA40



Datasheet text preview:
SanRex® SanRex
Fast & Soft Recovery Diode DBA100UA40
IF(AV)= 2x50A, VRRM=400V, trr=90ns
SanRex Fast & Soft Recovery Diode Module DBA100UA40 is designed for applications requiring fast switching and soft recovery wave shape to reduce or eliminate the need for snubber components in the circuit. The modules are isolated for easy mounting with other components or a common heatsink.

Features
* Very Fast Reverse Recovery Time * Soft Recovery Characteristics * Low Forward Voltage Drop * Compact isolated SOT-227 package

Isolated SOT-227 Package

Typical Applications
* Welding and Plasma Cutting Machines * DC chopper * Rectifier in Switch Mode Power Supplies (SMPS) * Uninterruptible Power Supplies (UPS) * Free Wheeling Diode in converters and motor control circuits

Internal schematic diagram

Symbol Item V RRM VR(DC) IF(AV) IFSM I2t Tj Tstg V ISO Repetitive Peak Reverse Voltage Reverse D.C. Voltage Average Forward Current Surge Forward Current I 2 t (for fusing) Junction Temperature Storage Temperature Isolation Voltage (R.M.S.) Mounting Mounting M4 Torque Terminal M4 Mass

Conditions

Tj = 25 C (unless otherwise noted) per diode Ratings Unit 400 320 50 490 1000 -40 to +150 -40 to +125 2500 1.5 1.5 30 V V A A A 2s °C °C V N·m g

°

D.C., T C = 99°C ½ cycle, 60Hz, Peak value, non-repetitive Value for one cycle surge current

A.C. 1 minute Recommended 1.0-1.4 Recommended 1.0-1.4 Typical Value

SanRex 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: semi@sanrex.com

SanRex® SanRex®
Fast & Soft Recovery Diode
Symbol Item IR R M VF M t
rr °

DBA100UA40
Tj= 25 C (unless otherwise noted) per diode Ratings Unit Min. Typ. Max. 100 mA 1.10 90 1.20 130 0.85 V ns °C/W

Conditions VR = VRRM, Tj= 150°C IF = 50A, Inst. measurement

Repetitive Peak Reverse Current Forward Voltage Drop Reverse Recovery Time Thermal Resistance

Rth(j-c)

IF = 50A, VR =200V, -di / dt = 100A/Fs Junction to case

* Dimensions in millimeters

SanRex 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: semi@sanrex.com




Others parts begin by db