PART NUMBER
EPA500-125 EPA500-150 EPA500-175 EPA500-200 EPA500-225 EPA500-250 EPA500-275 EPA500-300 EPA500-350 EPA500-400 EPA500-450 EPA500-500 EPA500-600 EPA500-700 EPA500-800 EPA500-900 EPA500-1000
Delay Times referenced from input to leading edges at 25°C, 5.0V, with no load.
DC Electrical Characteristics Parameter Test Conditions
VOH VOL VIK IIH High-Level Output Voltage Low-Level Output Voltage Input Clamp Voltage High-Level Input Current
Schematic Min Max Unit
V 0.5 V -1.2 V 50 µA 1.0 mA -2 mA -100 mA 75 mA 75 mA 4 nS 20 TTL LOAD 10 TTL LOAD
14 VCC 8 OUTPUT
VCC = min. VIL = max. I OH = max 2.7 VCC = min. VIH = min. I OL= max VCC = min. II = II K VCC = max. VIN = 2.7V VCC = max. VIN = 5.25V IIL Low-Level Input Current VCC = max. VIN = 0.5V IOS Short Circuit Output Current VCC = max. VOUT = 0. -40 ICCH High-Level Supply Current VCC = max. VIN = OPEN ICCL Low-Level Supply Current VCC = max. VIN = 0 TRO Output Rise Time Td 500 nS (0.75 to 2.4 Volts) NH Fanout High-Level Output VCC = max. VOH = 2.7V NL Fanout Low-Level Output VCC = max. VOL = 0.5V
INPUT 1
7 GROUND
Recommended Operating Conditions
VCC VIH VIL IIK IOH IOL PW* d* TA Supply Voltage High-Level Input Voltage Low-Level Input Voltage Input Clamp Current High-Level Output Current Low-Level Output Current Pulse Width of Total Delay Duty Cycle Operating Free-Air Temperature