Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: EE-SPW311

Category:
 Optoelectronics
   -> Photosensors
             -> Photomicrosensor

Description: EE-SPW311/411 Amplified Photomicrosensor Data Sheet

Company: Omron Corporation

Datasheet: Download EE-SPW311 datasheet     File size : 42 kB

Request For quote: Find where to buy EE-SPW311



Datasheet text preview:
EE-SPW311/411
Photomicrosensor with a Sensing Distance as Long as 1 m H Easy-to-see Light-ON indicator H W i d e o p e r a t i n g v o l t a g e r a n g e : 5 to

24 VDC H Light modulation effectively reduces external light interference H Easy-to-wire connector ensures ease of maintenance H Convert to PNP output with EE-2002 conversion connector

Ordering Information
Appearance Sensing m ethod S e n s i n g distance Through beam 1m Sensing object Opaque material, 5 m m di a . m i n . Output configuration Dark-ON Light-ON Weight Approximately 8.8 g Part number EE-SPW311 EE-SPW411

Note: Wire Harness/Connector included with EE-SPW311 and EE-SPW411

J ACCESSORIES
Name C o n n e c t o r fo r E m m i t t e r C o n n e c t o r fo r R e c e i v e r Part number EE-1006L EE-1006D

EE- SPW311/411 -

EE - SPW311/411 -

Specifications
J RATINGS
Item Supply v oltage Current consumption S e n s i n g di s t a n c e Standard reference object Directional angle Control output Output configuration Transistor on output stage without detecting object Transistor on output stage with detecting object Indicator (See Note.) Without detecting object With detecting object Transmissive type EE-SPW311 EE-SPW411 5 (-5%) to 24 (+10%) VDC, ripple (p-p): 10% max. 40 mA max. (emitter: 20 mA max.; receiver: 20 mA max.) 1m O p a q u e : 5 m m di a . m i n . 5 ° to 20 ° At 5 to 24 VDC: 100 mA load current (IC) with a residual voltage of 0.8 V max. When driving TTL: 40 mA load current (IC) with a residual voltage of 0.4 V max. OFF ON ON OFF 100 Hz max. (200 Hz typ.) Dedicated connectors: EE-1006L and EE-1006D GaAs infrared LED (pulse modulated) with a peak wavelength of 940 nm Si photo-transistor with a sensing wavelength of 850 nm max. ON OFF

R e s p o n s e fr e q u e n c y Connecting method Light source Receiver

Note: The indicator is a GaP red LED (peak emission wavelength: 700 nm).

J CHARACTERISTICS
Ambient illumination* Enclosure ratings Ambient temperature Ambient humidity Vibration resistance Shock resistance Material Cable l ength Operating Storage Operating Storage S e n s i n g f a c e : f l u o r e s c e n t l i g h t : 1, 0 0 0 x m a x . ; i n c a n d e s c e n t l i g h t : 3, 0 0 0 x m ax . IP60 -10°C to 55°C (14°F to 131°F) -25°C to 80°C (-13°F to 176°F) 45% to 85% 35% to 95% Destruction: 200 to 2,000 Hz (with a peak acceleration of 10G's), 1.5-mm double amplitude for 2 hrs (with 4-minute cycles) each in X, Y, and Z directions Destruction: 500 m/s2 (approx. 50G) for 3 times each in X, Y, and Z directions Case: PBT; lens: polycarbonate 10 m max. with a cross-sectional area of 0.3 mm2 min. (AWG24 min.)

Note: *The ambient illumination is measured on the surface of the receiver.

2

EE - SPW311/411 -

EE- SPW311/411 -

Engineering D ata
J RECEIVER OUTPUT VS. SENSING DISTANCE (TYPICAL) J PARALLEL MOVEMENT CHARACTERISTICS (TYPICAL)

Operating voltage

Distance Y (mm)

Excess gain

Y

X

Distance between sensors (cm)

Distance X (cm)

Operation
J INTERNAL/EXTERNAL CIRCUIT DIAGRAM
Light-ON/Dark-ON
5 to 24 VDC Operation indicator Load (relay) OUT Main circuit RL Connect RL only when a logic circuit is driven.

IC
Logic circuit 0V

J TIMING CHART
Light-ON
Incident Interrupted LIGHT indicator (red) Output transistor Load (relay) Output voltage (logic) ON OFF ON OFF Operates Releases H L LIGHT indicator (red) Output transistor Load (relay) Output voltage (logic)

Dark-ON
Incident Interrupted ON OFF ON OFF Operates Releases H L

3

EE- SPW311/411 -

EE - SPW311/411 -

Dimensions
Unit: mm (inch)

J EE-SPW311/SPW411
Emitter (EE-SPWL_11)
25.4 (1.00) 19 (0.75) 8 (0.31) 0.6 (0.02) 19 (0.75) 13.4 (0.53) 7.4 (0.29) Two, 3.2 dia. holes

Receiver (EE-SPWD_11)
25.4 (1.00) 19 (0.75) Two, 3.2 dia. holes

8 (0.31) 0.6 (0.02) 1.5 (0.06) 19 (0.75) 13.4 (0.53) Indicator Sensing window 7.4 (0.29)

Sensing window

27 (1.06)

Two, 3.8 dia. holes 27 (1.06) 15.1 (0.59) 14.1 (0.56)

Two, 3.8 dia. holes

15.1 (0.59) 14.1 (0.56)

6.2 (0.24)

5.5 (0.22) (1) (2) (3) 0.3 (0.01) 2.54 (0.10) 0.7 (0.03)

6.2 (0.24)

5.5 (0.22) (1) (2) (3) 0.3 (0.01) 2.54 (0.10) 0.7 (0.03)

Terminal Arrangement Emitter (1) V CC (2) OUT GND (0 V) (3)

Receiver (1) (2) OUT (3)

V CC OUTPUT GND (0 V)

J EE-1006L CONNECTOR FOR EMITTER (ATTACHMENT)
0.6 (0.02) (1) (2) (3) (4) 5.3 (0.21) 16.2 (0.64) 20 (0.79) 2,000 (78.74)

11.8 (0.46)

Terminal Arrangement (1) (4) Brown (Red) Blue (Black) V CC GND (0 V)

2.54 (0.10)

Note: Older standard colors are shown in parentheses. The connector comes with an 18 strand, 0.12-wire, 2-m attached RED CABLE.

J EE-1006D CONNECTOR FOR RECEIVER (ATTACHMENT)
0.6 (0.02) (1) (2) (3) (4) 2.54 (0.10) 5.3 (0.21) 16.2 (0.64) 20 (0.79) 2,000 (78.74)

11.8 (0.46)

Terminal Arrangement (1) (2) (3) Brown B l ac k Blue (Red) (White) (Black) V CC OUTPUT GND (O V)

Note: Older standard colors are shown in parentheses. The connector comes with an 18 strand, 0.12-wire, 2-m attached GRAY CABLE.

4

EE - SPW311/411 -

EE- SPW311/411 -

Precautions
Refer to the Technical Information Section for general precautions.

J CHEMICAL RESISTANCE
The sensing window is made of a polycarbonate resin which withstands chloride solvents and strong acids but is soluble i n strong alkali, aromatic hydrocarbons, and aliphatic hydrocarbonate c hloride s olvents.

3. Fix the position of the receiver (or emitter) securely, move the emitter (or receiver) horizontally and vertically to check the range in which the operation indicator is lit. Then locate the emitter (or receiver) in the center of the range, and fix the position securely.

J AXIS ADJUSTMENT
1. When mounting the emitter and receiver, ensure that the center line of each lens will be on the same plane (refer to the diagrams). S ide view

J CONNECTION
Extra care must be taken when making connections to the units because they are protected against reverse polarity. Install the wiring for the photomicrosensor in a separate wiring duct well away from both supply lines and high voltage cables to prevent damage or faulty operation from i nduced transients.

Top view

Any extension m ust be s horter than 10 meters with wire that has a cross-sectional area greater than 0.3 mm2.

J POWER SUPPLY
When using a commercial switching regulator, the frame ground (FG) and ground (G) pins must be grounded. Failure to do so may result in faulty operation due to switching noise. 2. Turn on the emitter and receiver after making sure that they have been wired correctly. When power is turned on, the operation indicator on the receiver will light. Make sure the operation indicator is off when an object intercepts the optical axis and the operation indicator lights again when the object is removed.

J LOADS
Operate the sensor with a l oad. The s ensor is not protected against s hort c ircuits. When the photomicrosensor is turned on, a period of approximately 1 to 3 ms is required for the photomicrosensor to operate stably.

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.

R

OMRON ELECTRONICS LLC

1-800-55-OMRON
Cat. No. GC APMS-1 09/02

One East Commerce Drive Schaumburg, IL 60173

OMRON ON - LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to change without notice.

OMRON CANADA, INC.

416-286-6465

885 Milner Avenue Toronto, Ontario M1B 5V8

Printed in U.S.A.




Others parts begin by ee
EE-1   EE-2   EE-3