Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: E8CC-AN0C

Category:
 Sensors
   -> Pressure Sensors

Description: E8CB/E8CC Pressure Sensor Data Sheet

Company: Omron Corporation

Datasheet: Download E8CC-AN0C datasheet     File size : 1657 kB

Request For quote: Find where to buy E8CC-AN0C



Datasheet text preview:
R

Pressure Sensor

E8CB/E8CC

Flat-pack, Slim, DIN-rail Mount Pressure Sensor H Withstands a pressure of 490 kPa
(71 psi) H Easy pressure setting with a two-turn pressure adjuster H Linear analog output H E8CC has digital display

Ordering Information
J SENSOR
Digital display Pressure range No Positive pressure Negative pressure Yes Positive pressure Negative pressure Positive pressure 0 to 98 kPa (0 to 14.2 psi) 0 to - 101 kPa (0 to - 14.6 psi) 0 to 98 kPa (0 to 14.2 psi) 0 to - 101 kPa (0 to - 14.6 psi) 0 to 980 kPa (0 to 142.1 psi) ON/OFF output NPN open collector Li near output 1 to 5 V Part number E8CB -01C E8CB -CN0C2B E8CC -A01C E8CC -AN0C E8CC -B10C

2

E8CB/E8CC

E8CB/E8CC

Specifications
J RATINGS/CHARACTERISTICS
Item/Model E8CB-01C E 8C B C N 0C 2B (See Note 2.) E8CC-A01C E8CC-AN0C (See Note 2.) E8CC-B10C

Supply voltage Current consumption Pressure type Permissible pressure range (See Note 2.) Pressure setting range (See Note 2.) Display value Reference value Display value Reference value Pressure indication unit Withstand pressure Applicable material Repeat accuracy (ON/OFF output) Accuracy (linear output) Differential travel (ON/OFF output) Linearity (linear output) Response time Linear output ON/OFF output Load current Output applied voltage Residual voltage Circuit protection Display (See Note 1.) Display accuracy

12 to 24 VDC ±10% with a ripple (p-p) of 5% max. 20 mA max. Gauge pressure 0 to 1 kgf/cm2 0 to 98 kPa (0 to 14.2 psi) 0 to 1 kgf/cm2 0 to 98 kPa (0 to 14.2 psi) --490 kPa (71 psi) 0 to - 76 cmHg 0 to - 101 kPa (0 to - 14.6 psi) 0 to - 76 cmHg 0 to - 101 kPa (0 to - 14.6 psi) 0 to 98 kPa --(0 to 14.2 psi) 0 to 98 kPa --kPa 490 kPa (71 psi) 1.5 MPa (217.5 psi) 0 to - 101 kPa --(0 to - 14.6 psi) 0 to - 101 kPa --0 to 980 kPa --(0 to 142.1 psi) 0 to 9 8 0 kP a --30 mA max.

Noncorrosive and nonflammable gases ±1% FS max. ±3% FS max. 2% FS max. ±1% FS max. 5 ms max. 1 to 5 V with an output impedance of 20 and a permissible resistive load of 10 k min. NPN open collector 80 mA max. 30 VDC max. 1 V max. (with a load current of 80 mA) and 0.4 V max. (with a load current of 20 mA) Reversed power supply connection and load short-circuiting Red LED ON with output transistor turned ON --21/2-digit display Red LED ON with output transistor turned ON ±3% FS ± 1 digit max. within a temperature range from 0°C to 50°C (32°F to 122°F) ±4% FS ± 1 digit max. within a temperature range from 50°C to 55°C (122°F to 131°F) ±5% FS ± 1 digit max. within a temperature range from 0°C to - 10°C (32°F to 14°F)

3

E8CB/E8CC

E8CB/E8CC

Item/Model

E8CB-01C

E 8C B C N 0C 2B (See Note 2.)

E8CC-A01C

E8CC-AN0C (See Note 2.)

E8CC-B10C

Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection (See Note 3.) Pressure port Connection method Weight Pressure port

Operating: - 10°C to 55°C (14°F to 131°F) with no icing Storage: - 25°C to 70°C (- 13°F to 158°F) with no icing Operating/Storage: 35% to 95% (with no icing) ±0.12% FS/°C between 0°C and 50°C (32°F to 122°F) and ±0.2% FS/°C max. between - 10°C and 0°C or 50°C and 55°C (122°F to 131°F) ±1.5% FS max. 50 M min. (at 500 VDC) between current carrying parts and case 1,000 VAC for 1 min 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s2 (328 ft/s2) for 2 hours each in X, Y, and Z directions 1,000 m/s2 (3280 ft/s2) 3 times each in X, Y, and Z directions IEC60529 IP50 Aluminum Prewired (standard cable length: 2 m) Approx. 70 g (2.47 oz) NPT 1/8 and M5 female screws Approx. 80 g (2.82 oz)

Note: 1. The 21/2-digit display refers to a display in which the third digit displays only 0 or 1. 3rd digit 2nd digit 1st digit

0 or 1

0 to 9

0 to 9

2. These models are negative-pressure models. 3. E8CB and E8CC are not oil resistant or water resistant.

Engineering Data
J TEMPERATURE VS LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CB-01C
Linear output fluctuation (% FS)

J PRESSURE VS LINEAR OUTPUT VOLTAGE (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS) Pressure (kgf/cm2)

Temperature (°C)

4

Linear output voltage (V)

E8CB/E8CC
J TEMPERATURE VS OPERATING PRESSURE (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS)

E8CB/E8CC
J LINEARITY (TYPICAL)
E8CB-01C
Linearity deviation (%FS)

Temperature (°C)

Pressure (kgf/cm2)

J VOLTAGE VS. OPERATING PRESSURE FLUCTUATION (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS)

J VOLTAGE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CB-01C
Linear output fluctuation (% FS)

Voltage (V)

Voltage (V)

J TEMPERATURE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CC-A01C
Linear output fluctuation (% FS)

J PRESSURE VS. LINEAR OUTPUT VOLTAGE (TYPICAL)
E8CC-A01C

Linear output voltage (V)

Temperature (°C)

Pressure (kgf/cm2 ) Pre ssu re (cmH g ) Pressure (kPa)

5

E8CB/E8CC
J TEMPERATURE VS. OPERATING PRESSURE (TYPICAL)
E8CC-A01C
Operating pressure fluctuation (% FS)

E8CB/E8CC
J LINEARITY (TYPICAL)
E8CC-A01C

Linearity deviation (%FS)

Temperature (°C)

Pressure (kgf/cm2 ) Pressure (kPa)

J VOLTAGE VS. OPERATING PRESSURE FLUCTUATION (TYPICAL)
E8CC-AN0C
Operating pressure fluctuation (% FS)

J VOLTAGE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CC-AN0C
Linear output fluctuation (% FS)

Voltage (V)

Voltage (V)

6




Others parts begin by e8