R
Ultrasonic Sensor With Zone Sensing
Through-beam, Reflective and Zone Models H 1 m through-beam for long range
applications
E4B
H Narrow beam angle of 8° detects
objects as small as 2 x 2 cm
H Zone models detect objects smoothly
while suppressing interference from background objects
H 200 kHz provides high immunity from
environmental noise
H User-selectable normally open and
normally closed operation
Ordering Information
Supply voltage 12 to 24 VDC Sensing type Through-beam Sensing distance 1m 50 cm Zone setting Distance setting 20 to 70 cm 20 to 70 cm 5 to 20 cm Cable length 2m 5m 2m 5m 2m 5m 2m 5m 2m 5m Part number NPN output E4B -T1E4 2M E4B -T1E4 5M E4B -TS50E4 2M E4B -TS50E4 5M E4B -RS70E4 2M E4B -RS70E4 5M E4B -LS70E4 2M E4B -LS70E4 5M E4B -LS20E4 2M E4B -LS20E4 5M PNP output E4B -T1F4 2M E4B -T1F4 5M E4B -TS50F4 2M E4B -TS50F4 5M E4B -RS70F4 2M E4B -RS70F4 5M E4B -LS70F4 2M E4B -LS70F4 5M E4B -LS20F4 2M E4B -LS20F4 5M
2
E4B
J SENSING TYPE
Through-beam
Detects the attenuation or interrupted condition of the ultrasonic beam caused by the object E4B-TjS Emitter passing between the Emitter and Receiver. Sensing object
E4B
E4B-TjR Receiver
Reflective
Setting distance
Detects only the beam reflected from the object existing within the sensing distance range set with the distance adjuster.
Distance adjustment E4B-LSj
Unstable range
Sensing object Sensing distance adjustable range
Setting zone
Sensing background
Detects the object with the interruption of the normal beam reflected from the acoustically reflective surface. E4B-RS70
Sensing object
Acoustically reflective surface
Sensing target
Detects only the beam reflected from the object existing in the sensing range set with the distance selector.
E4B-RS70
Unstable range
Sensing object
Note: An object may be detected due to multiple reflection if the object is in the unstable range where the distance adjuster is ineffective, in which case however, the detection of the object will not be stable. Therefore, do not attempt to use the E4B to detect an object in the unstable range.
3
E4B
E4B
Specifications
J RATINGS/CHARACTERISTICS
Part number Sensing method Supply voltage Current consumption 12 V D C E4B-TS50E4 Through-beam Emitter: 155 mA max. Receiver: 30 mA max. Emitter: 80 mA max. Receiver: 30 mA max. 50 cm (19.69 in) Emitter: 70 mA max. Receiver: 30 mA max. Emitter: 50 mA max. Receiver: 30 mA max. 1 m (3.28 ft) E4B-T1E4 E4B-LS20E4 Distance setting E4B-LS70E4 E4B-RS70E4 Zone setting
12 to 24 VDC ± 10% (10.8 to 26.4 VDC) with a max. ripple ±10% (p-p) 100 mA max.
24 V D C
50 mA max. 5 to 20 cm (1.97 to 7.87 in) 20 to 60 cm (20 to 70 cm) (See Note 1.) (7.87 in to 23.62 in) 20 to 60 cm (20 to 70 cm) (See Note 1.) (in 10-cm divisions) (7.87 to 23.62 in) 3 cm max.
Sensing distance
Standard sensing object Differential travel Directional angle (See Note 2.) Ultrasonic oscillation frequency Switching frequency (See Note 3.) Response time Operating mode Control output Residual voltage Indicators Ultrasonic speed compensation Ambient operating temperature Relative humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Enclosure rating Approvals UL, cUL Weight (with 2-m-long cord and Mounting Bracket) N PN PN P
10 x 10 cm flat plate -- ±8° max. 200 kHz 50 H z 10 ms 10 H z 50 ms
4 x 4 cm flat plate 20% max. of sensing distance
50 H z 10 ms
20 H z 25 ms
N.O. or N.C. selectable 100 mA at 30 VDC (with a residual voltage of 1.5 V max.) and an output resistance of 4.7 k 1.5 V max. under a load current of 100 mA SENSING indicator (red LED) and STABILITY indicator (green LED) No - 10°C to 55°C (14°F to 131°F) 35% to 95% ±10% max. of sensing distance at 20°C (68°F) in the temperature range of - 10°C and 55°C (14°F to 131°F) ±5% max. of sensing distance at a voltage between 90% and 110% of the rated power supply voltage 20 M min. at 500 VDC between current carry parts and case 1,000 V (50/60 Hz) for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z axes 500 m/s2 (approx. 50G) 3 times each in X, Y, and Z axes IEC IP66 (water resistant) Recognized, File No. E41515 when used with a Class 2 power source Approx. 600 g (21 oz) with Emitter and Receiver Approx. 300 g (10.6 oz) Yes
Note: 1. These are the available sensing distances at an ambient temperature range between 0°C and 45°C (32°F to 113°F) 2. Signal attenuation of - 6 dB. 3. The switching frequencies are values obtained with the E4B used for detecting a rotating propeller-shaped disc as shown below.
Space:Blade = 1:1
4
E4B
E4B
Operation
J OUTPUT CIRCUITS
NPN Output DC
Brown Signal received, output on (Power supply polarity: Brown: +; Blue: 0 V) Signal received Signal interrupted STABILITY indicator (red) Note 2. Blue Output transistor ON OFF ON OFF Signal not received, output on (Power supply polarity: Brown: 0 V: Blue: +) Sound incident Sound interrupted STABILITY indicator (red) Output transistor ON OFF ON OFF
+V Load
Note 1.
Ma i n ci rcu i t
4.7k W
Black
0V Note: 1. 100 mA max. (load current) 2. Required when the transistor circuit is connected.
Load (relay)
Operate Release H L
(B lu e B la ck) (B ro wn B la ck)
Operate Load (relay) Release H L
(B lu e B la ck)
Output voltage (logic)
Output voltage (logic)
(B ro wn B la ck)
PNP Output
(No Diagram Provided)
5
E4B
E4B
Engineering Data
J OPERATING DISTANCE VS. SENSING OBJECT SIZE (TYPICAL)
E4B-TS50E4, E4B-T1E4
Minimum Sensing object size (cm) for stable operation
Sensing position
E4B-LS20E4
Dia. (d) of sensing object or length (W) of one side in cm.
E4B-LS70E4, E4B-RS70E4
Dia. (d) of sensing object or length (W) of one side in cm.
Sample: Round pipe that is 10 cm long mi n .
E4B-T1E4: Sensitivity adjuster set to Max.
Sample: Round pipe that is 10 cm long mi n .
E4B-TS50E4: Sensitivity adjuster set to Max. Sensitivity adjuster: Adjust with stable incident.
Sensitivity adjuster: Adjust with stable incident.
Sensing position X (cm) (from Receiver)
Sensing distance (cm)
Operating distance (cm)
J OPERATING RANGE DIAGRAM (TYPICAL)
E4B-LS20E4
Standard sensing object (40 x 40 flat plate)
J OPERATING DISTANCE VS. SENSING OBJECT ANGLE (TYPICAL)
E4B-LS70E4, E4B-RS70E4
Standard sensing object (40 x 40 flat plate) 5 5 -d i a . ro d 3 0 -d i a . ro d
E4B-LS70E4, E4B-RS70E4
Angle Sensing object Distance X
Sensing distance (cm)
Sensing distance (cm)
E4B-LS70 E4B-RS70
A ngl e ( ) °
Stable operating range
Sensing distance (cm)
Sensing distance (cm)
Operating distance X (cm)
6