Datasheet text preview:
SCOPE:
MICROPOWER INVERTING SWITCHING REGULATOR Generic Number MAX634M(x)/883B
Device Type 01
Case Outline(s). The case outlines shall be designated in Mil-Std-1835 and as follows: Outline Letter JA Mil-Std-1835 GDIP1-T8 or CDIP2-T8 Case Outline Package Code 8 LEAD CERDIP J8
Absolute Maximum Ratings Supply Voltage, +VS to GND 1/ ...... +18V Input Voltage, CX , LBR, VFB 2/ .... -0.3V to(+VS+0.3V) LX Output Current ...... 525mA Peak LBO Output Current ........ 50mA Lead Temperature (soldering, 10 seconds) ............ +300°C Storage Temperature ....... -65°C to +150°C Continuous Power Dissipation ...TA=+70°C 8 lead CERDIP(derate 8.0mW/°C above +70°C) .......... 640mW Junction Temperature TJ .... +150°C Thermal Resistance, Junction to Case 8 lead CERDIP, JC: ..... 55°C/W Thermal Resistance, Junction to Ambient 8 lead CERDIP. JA: ........... 125°C/W Recommended Operating Conditions. Ambient Operating Range (TA) ............ -55°C to +125°C ORDERING INFORMATION 01 MAXIM PART NUMBER MAX634MJA/883B SMD NUMBER 5962-9212401MPA
TERMINAL NUMBER 1 2 3 4 5 6 7 8
8 LEAD CERDIP LBR LBO CX GND LX VS+ VREF VFB
NOTE 1: In addition to the absolute maximum rating of +18V, the input voltage must not exceed 24V- - VOUT. NOTE 2: The input rating may be exceeded if the input current is limited to 1mA or less. Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
----------------------------
Electrical Characteristics of MAX634/883B for /883B and SMD 5962-92124
19-0035 Page 2 of
Rev. C 5
TABLE 1 ELECTRICAL TESTS PARAMETER Symbol CONDITIONS -55 °C TA +125°C +VS=+5.0V, GND=0V Unless otherwise specified Voltage at VOUT +VS=5.0V, No ext load, LX off +VS=15V, No ext load, LX off Reference Voltage VREF R1=300k, R2=75k, R1 and R2 give a nominal output voltage of -5V. R1=900k, R2=75k, R1 and R2 give a nominal output voltage of -15V. NOT E 5 VS=5V to 15V, R1=300k, 4/ R2=75k. R1 and R2 give a nominal output voltage of -5V. IL=1mA to 15mA, R1=300k, 4/ R2=75k. R1 and R2 give a nominal output voltage of -5V. NOT E 5 IX=100mA VLX=-18V 1 2,3 1 2,3 1 2,3 1 1 2,3 1 2,3 1 1 1 2,3 1,2,3 1 1 VLBO=0.4V, VLBR=1.15V VLBO=16.5V, VLBR=+1.35V 1,2,3 1,2,3 All All All 1 .2 2 1.18 -5.20 -5.25 -15.70 -16.00 80 -2.0 -3.0 Group A Subgroup 1 2,3 1,2,3 Device type All All 50 1.28 1.32 -4.80 -4.75 -14.30 -14.00 % %/VOUT %/VOUT kHz µA V nA nA µA 3.0 µA Limits Min 3/ 2 .3 2.6 Limits Max 3/ 16.5 16.5 150 Units
Operating Voltage Supply Current
+VS
V µA V
IIN
Output Voltage
VOUT
All
V
Efficiency Line Regulation
VRLINE VRLOAD fO RON ILX VLRB ILRB IFB ILBO ILBOL
2.0 3.0 0 .4 0.5
Load Regulation
All
Operating Frequency Range LX On Resistance LX Leakage Current Low Battery Input Threshold LowBattery Input Bias Current Feedback Input Bias Current Low Battery Output Current Low Battery Output Leakage Current NOTE 3:
All All All All All All All All
0 .1
75 16 1 .0 20 1.35 10 10
1.15
500
The algebraic convention, whereby the most negative value is a minimum and the most positive a maximum, is used in this table. Negative current shall be defined as conventional current flow out of a device terminal. NOTE 4: Guaranteed by correlation with dc pulse measurements. NOTE 5: The parameter is guaranteed by design, but not tested.
----------------------------
Electrical Characteristics of MAX634/883B for /883B and SMD 5962-92124
19-0035 Page 3 of
Rev. C 5
QUALITY ASSURANCE Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in MilStd-883. Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015: 1. Test Condition, A, B, C, or D. 2. TA = +125°C minimum. 3. Interim and final electrical test requirements shall be specified in Table 2. Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B, C, and D inspection. Group A inspection: 1. Tests as specified in Table 2. 2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted. Group C and D inspections: a. End-point electrical parameters shall be specified in Table 1. b. Steady-state life test, Method 1005 of Mil-Std-883: 1. Test condition A, B, C, D. 2. TA = +125°C, minimum. 3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883. TABLE 2. ELECTRICAL TEST REQUIREMENTS Mil-Std-883 Test Requirements Interim Electric Parameters Method 5004 Final Electrical Parameters Method 5005 Group A Test Requirements Method 5005 Group C and D End-Point Electrical Parameters Method 5005 * PDA applies to Subgroup 1 only. Subgroups per Method 5005, Table 1 1 1*, 2, 3 1, 2, 3 1
----------------------------
Electrical Characteristics of MAX634/883B for /883B and SMD 5962-92124
19-0035 Page 4 of
Rev. C 5