Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: D1D20

Category:
 Discrete
   -> Solid State relays

Description: N/A0.02-20 Amps DC0-100 Volts DC3.5-32 Control - Volts DC

Company: Crydom Corporation

Datasheet: Download D1D20 datasheet     File size : 222 kB

Request For quote: Find where to buy D1D20



Datasheet text preview:
Series 1-DC
7-40Amp · 0-500 Vdc · DC Output
· M OSFET Output · Low On-State Resistance · Paralleling Capability for Higher Currents · Panel M ount
DC output relays feature MOSFET technology for low on-state resistance, assuring easy paralleling and switching capabilities to 40 amps at 100 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.

OUTPUT SPECIFICATIONS
MODEL NUMBERS
Operating Voltage Range [Vdc] Max. Load Current [Adc] Min. Load Current [mA] Max. Surge Current, [Adc] (10Msec) Max. On-State Voltage Drop @ Rated Current [Vdc] Thermal Resistance Junction to Case [RJC] C/W Max On-state Resistance @ Rated Current (RDS-ON) [Ohms] Max. Off-State Leakage Current @ Rated Voltage [mA] Max. Turn-On Time [”sec] Max. Turn-Off Time [msec]

D1D07 D1D12 D1D20 D1D40

D2D07 D2D12

D4D07 D4D12

D5D07 D5D10

0-100 7 20 15 2.0 2.2 .29 0.1 100 1.0

0-100 0-100 0-100 12 20 28 1.6 1.34 .13 0.2 100 1.0 20 20 42 2.1 1.06 .10 0.3 100 1.0 40 20 106 2.1 0.83 .05 0.3 100 1.0

0-200 0-200 7 20 22 2.0 1.5 .29 0.1 100 1.0 12 20 27 2.8 1.06 .23 0.3 100 1.0

0-400 0-400 7 20 17 4.2 1.06 .6 0.3 100 1.0 12 20 36 4.2 0.8 .35 0.3 100 1.0

0-500 0-500 7 20 19 5.7 1.0 .8 0.2 100 1.0 10 20 29 5.5 0.8 .55 0.3 100 1.0

I N P U T SPECIFICATIONS
Control Voltage Range Maximum Turn-On Voltage Minimum Turn-Off Voltage Nominal Input Impedance Maximum Input Current

D C CONTROL
3.5-32 Vdc 3.5 Vdc 1.0 Vdc See Note 4 1.6 mA (5 Vdc), 28 mA (32 Vdc)
©2001 CRYDOM CORP, Specifications subject to change without notice.

GENERAL NOTES

All parameters at 25șC unless otherwise specified. Dielectric strength and insulation resistance are measured between input and output. Heat sinking required, for derating curves see page 3. Input circuitry incorporates active current limiter.

FastFax Document No. 164 SERIES 1DC. REV. 011602 PAGE 1 OF 3

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506

Series 1-DC
7-40Amp · 0-500 Vdc · DC Output
GENERAL SPECIFICATIONS

Dielectric Strength 60Hz Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range
M E C H A N I C A L SPECIFICATIONS Weight: (typical)

2500 Vrms 109 Ohm 50 pF -30 to 80șC -40 to 125șC 3.0 oz. (86.5g) Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted
M A X I M U M SURGE vs. DURATION

Encapsulation: Terminals:
1.10 (27.9) .45 (11.4)

MOUNTING HOLE/SLOT 0.17 (4.3) DIA.

8-32 TERMINAL (2 PLACES )
M A X . SURGE CURRENT (Amps)

60 55 50 45 40 35 30 25 20 15 10 5

D1D20

-1.87 (47.5)

OUTPUT

+
2 3

1
SOLID-STATE RELAY

4

2.30 (58.4) 1.70 (43.2)

D1D12 D2D12

--

INPUT

+

D1D07

D2D07

1.00 (25.4) 1.80 (45.7)

6-32 TERMINAL (2 PLACES)

.78 (19.8) .90 (22.9)

2

3 4 5 6 8 10

2 3 4 5 6 8102 2 3 4 5 6 8103 S U R G E DURATION (msec)

2

3 4 5 6 8104

All dimensions are in inches (millimeters)
60 M A X . SURGE CURRENT (Amps)

Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.)

55 50 45 40 35 30 25 20 15 10 5 2 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 S U R G E DURATION (msec) 2 3 4 5 6 8104 D5D07 D4D07 D5D10 D4D12

Input and output polarity must be observed. Inductive loads must be diode suppressed.

4 (­) DC CONTROL SOURCE

1 (­)
LOAD OUTPUT

INPUT

SSR

M A X . SURGE CURRENT (Amps)

(­) (+)

200

D1D40 150

3 (+)

2 (+)

Transient Protection
All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage.

100

50

2

3 4 5 6 8 10

2 3 4 5 6 8102 2 3 4 5 6 8103 S U R G E DURATION (msec)

2

3 4 5 6 8104

©2001 CRYDOM CORP, Specifications subject to change without notice.

APPROVALS UL E116950 (100 Volt Models Only)

FastFax Document No. 164 SERIES 1DC. REV. 011602 PAGE 2 OF 3

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506

Series 1-DC
7-40Amp · 0-500 Vdc · DC Output
Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details.

C U R R E N T DERATING CURVES
D1D07 - 7A
16
2șC/W
Base Plate Temp [șC] Power Dissipation Power Dissipation

D1D12 - 12A
90 24 20 16 12 8
NO HEATSINK 2șC/W
Base Plate Temp [șC]

D1D20 - 20A
90 45
1șC/W

80 90 100
4șC/W
Base Plate Temp [șC] Base Plate Temp [șC] Base Plate Temp [șC]

100

100
4șC/W 6șC/W

Power Dissipation

12 8 4

4șC/W 6șC/W

30

2șC/W

110
NO HEATSINK

110

15
6șC/W NO HEATSINK

110 120 80

120 0 1 2 3 4 56 7 20 40 60 80
Load Current [Adc] Max Ambient Temp. [șC]

4 0 2 4 6 8 10 12 20 40 60 80
Load Current [Adc]

120 0 4 8 12 16 20

20

40

60

Max Ambient Temp. [șC]

Load Current [Adc]

Max Ambient Temp. [șC]

D1D40 - 40A
90
0.2șC/W 0.5șC/W

D2D07 - 7A
80
Base Plate Temp [șC] Power Dissipation

D2D12 - 12A
95
2șC/W 4șC/W 6șC/W
Base Plate Temp [șC]

18 15 12 9 6
NO HEATSINK

40
1șC/W
Power Dissipation

85

100

Power Dissipation

30 20

60

2șC/W 4șC/W

1șC/W 1.5șC/W

100

100 110

110

30

2șC/W

120

6șC/W

3
NO HEATSINK

10
NO HEATSINK

120 0 1 2 3 4 5 67 20 40 60 80 2 4 6 8 10 12

120 80

0 8 16 24 32 40 20 40 60 80
Load Current [Adc]

140

0
Load Current [Adc] Max Ambient Temp. [șC]

20

40

60

Max Ambient Temp. [șC]

Load Current [Adc]

Max Ambient Temp. [șC]

D4D07 - 7A
40
2șC/W
Power Dissipation

D4D12 - 12A
85
Base Plate Temp [șC]

D5D07 - 7A
85 0.5șC/W 100 110 120 80 0 1 2 3 4 5 67 20 40 60 80
Load Current [Adc] Max Ambient Temp. [șC] Power Dissipation

60 50
Power Dissipation

40
1șC/W
Base Plate Temp [șC]

85
2șC/W

1șC/W

30 100 20 10
NO HEATSINK 4șC/W 6șC/W

1șC/W

30 20 10

40 30

2șC/W 4șC/W

100
4șC/W 6șC/W

110 120 80

110 120

20 10 0 2 4 6 8 10 12
NO HEATSINK

NO HEATSINK

0 1 2 3 4 5 67 20 40 60
Load Current [Adc] Max Ambient Temp. [șC]

20

40

60

Load Current [Adc]

Max Ambient Temp. [șC]

D5D10 - 10A
60 50
Power Dissipation

75
0.5șC/W 1șC/W
Base Plate Temp [șC]

©2001 CRYDOM CORP, Specifications subject to change without notice.

40
2șC/W

90

30 20 10
NO HEATSINK 4șC/W

105

120 80

0 2 4 6 8 10 20 40 60
Load Current [Adc] Max Ambient Temp. [șC]

FastFax Document No. 164 SERIES 1DC. REV. 011602 PAGE 3 OF 3

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506




Others parts begin by d1