Datasheet text preview:
Series 1
10-90Amp · 120, 240 Vac · AC Output

· Zero Voltage and Random Turn-On Switching · Panel Mount · 600V Transient Capability · Internal Snubber · 110 & 125A Models Available · Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P)
MODEL NUMBERS AC CONTROL D C CONTROL A1210 D1210 A1225 D1225 A1240 D1240 A2410 D2410

Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turnon (phase controllable) and normally closed (Form B) versions with either AC or DC input (coil) control. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.
A2425 D2425 A2450 D2450 A2475 D2475 A2490 D2490

O U T P U T SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] Max. Load Current

24-140 10 40 400 120 1.6 1.48 60 8 500

24-140 25 40 400 250 1.6 1.02 260 8 500

24-140 40 40 400 625 1.6 0.63 1620 8 500

24-280 10 40 600 120 1.6 1.48 60 10 500

24-280 25 40 600 250 1.6 1.02 260 10 500

24-280 50 40 600 625 1.6 0.63 1620 10 500

24-280 75 40 600 1000 1.6 0.31 4150 10 500

24-280 90 40 600 1200 1.6 0.28 6000 10 500

[Arms]

Min. Load Current, [mArms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (R JC [°C/W] ) Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load




0.5

1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) 0.5 0.5 0.5 0.5 0.5 0.5 0.5

I N P U T SPECIFICATIONS
Control Voltage Range Max. Reverse Voltage Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current

D C CONTROL
3-32 Vdc -32 Vdc 3.0 Vdc 1.0 Vdc 1500 Ohms

A C CONTROL
90-280 Vrms (60Hz) --90 Vrms 10 Vrms 60K Ohms 2mA @ 120 Vrms, 4mA @ 240 Vrms

AC CONTROL
(E SUFFIX)

18-36 Vrms --18 Vrms 4.0 Vrms 9.0K Ohms 3mA @ 24 Vrms

3.4mA @ 5 Vdc, 20mA @ 28Vdc

G E N E R A L NOTES

© 2002 CRYDOM CORP, Specifications subject to change without notice.

All parameters at 25° C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 3. Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).

FastFax Document No. 151 SERIES1 Rev. 042302 PAGE 1 OF 3

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506

Series 1
10-90Amp · 120, 240 Vac · AC Output
GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range M E C H A N I C A L SPECIFICATIONS Weight: (typical) Encapsulation: Terminals: A V A I L A B L E OPTIONS -B Normally Closed (Form B) Example: D2450-B, A2450-B E F 24 Vac Input (18-36 Vac) Example: A2450E Faston Terminals (Up to 50A Models) Example: D1225F Input Status LED. Agencies Approval Pending Example: D2450G Note: Control Voltage Range 4.5-32Vdc for DC Control Models. Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: D2425P 400 Hz Operation 10-50 Amp Models Only Zero Cross Switching Only Example: 4D2450 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D2450-10
Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs
1.87 (47.5)

4000 Vrms 109 Ohm 8 pF -40 to 80°C -40 to 125°C

3.0 oz. (86.5g) Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted
1.10 (27.9) .45 (11.4)

MOUNTING HOLE/SLOT 0.17 (4.3) DIA.

8-32 TERMINAL (2 PLACES )

1
1.87 (47.5)

OUTPUT

2

SOLID-STATE RELAY

-4
INPUT

+
3

2.30 (58.4) 1.70 (43.2)

G

BASE PLATE .125 (3.2)

1.00 (25.4) 1.80 (45.7)

6-32 TERMINAL (2 PLACES)

.78 (19.8) .90 (22.9)

P

MOUNTING HOLE/SLOT 0.17 (4.3) DIA.

1.10 (27.9) .45 (11.4)

FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2)

4D

1

OUTPUT

2

2.30 (58.4) 1.70 (43.2)

SOLID-STATE RELAY

4

-INPUT

+
3

-10

BASE PLATE .125 (3.2)

Ordering System: Combination of the suffixes should be made in the following order: EFPG-10. Crydom Heat Sinks offer excellent Example: A2450EFPG-10 thermal management and are per -

1.00 (25.4) 1.80 (45.7)

FASTON TERMINAL .187 X .032 (2 PLCS.)

.78 (19.8) .90 (22.9)

fectly matched to the load current rat ings of Crydom panel mount relays. Request Crydom's Heat Sink specifica tion sheet for all the details.

All dimensions are in inches (millimeters)

APPROVALS UL E116949 CSA LR81689 VDE 10143 UG (Not Applicable: -B and 4D)
FastFax Document No.151 SERIES1 Rev. 042302 PAGE 2 OF 3

© 2002 CRYDOM CORP, Specifications subject to change without notice.

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506

Series 1
10-90Amp · 120, 240 Vac · AC Output

C U R R E N T DERATING CURVES
10A
12
7°C/W 9°C/W 3°C/W

25A
30
1°C/W

95
Base Plate Temp [°C] Base Plate Temp [°C]

5°C/W

Base Plate Temp [°C]

110

25
Power Dissipation
3°C/W 2°C/W

100

Power Dissipation

8
NO HEATSINK

20 15 10
NO HEATSINK

115

110

4

120

5 0 2 4 6 8 10 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]

120 5 10 15 20 25 20 40 60 80

0
Load Current [Arms] Max Ambient Temp. [°C]

50A
60
1°C/W 1.5°C/W .5°C/W

75A
120 90
Base Plate Temp [°C] Base Plate Temp [°C]

90A
120
.5°C/W .2°C/W .4°C/W

90

95
Power Dissipation
.5°C/W .3°C/W

Power Dissipation

40
2°C/W

100

80
1°C/W

100

Power Dissipation

80
1°C/W

100

20
NO HEATSINK

110

110 40 120 0

110 40 120 0 20 40 60 80 0 20 40 60 80

120 80 15 30 45 60 75 20 40 60 80

0 10 20 30 40 50 20 40 60
Load Current [Arms] Max Ambient Temp. [°C]

Load Current [Arms]

Max Ambient Temp. [°C]

Load Current [Arms]

Max Ambient Temp. [°C]

© 2002 CRYDOM CORP, Specifications subject to change without notice.

FastFax Document No.151 SERIES1 Rev. 042302 PAGE 3 OF 3

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506