Part: S3000-M12

Category:

Description: Fan Monitor

Company:

Datasheet: Download S3000-M12 datasheet     File size : 335 kB

Request For quote: Find where to buy S3000-M12



Datasheet text preview:
thermal management systems
Speed Control Temperature dependent speed control is provided for any number of PAPST DC fans or blowers up to a total power capacity of 65W. The control module makes use of up to 4 thermistors which can be located in the most heat sensitive areas within the equipment. The module provides linear control between half and full speed. This is achieved by utilising one of the four user selected temperature
Alarm Functions and Outputs In the event of the measured temperature exceeding the upper selected level T2, a dual output alarm is activated, one output in the form of a single pole change-over relay with volt-free contacts and the other as an open collector. The same dual alarm arrangement is provided in the event of a thermistor failure. An open collector output is also provided should the module switch to shutdown/ standby mode. Features The System 3000 Module offers advanced control for thermal management systems providing: · Temperature dependant speed control · Multiple point temperature sensing · Can control any number of fans or blowers up to 65W total power consumption · Modules available for 12, 24 or 48VDC PAPST fans · Alarm outputs for over temperature and
system 3000 control module
Description The System 3000 is a comprehensive solution for the control and monitoring of PAPST DC fans, together providing a thermal management system for electronic equipment. It offers a modular approach enabling the Control Module to function as a separate fan speed controller or as a complete system integrated with the Monitor Module.
programs available which sets temperature parameters T1 (lower level) and T2 (upper level). As the surrounding ambient temperature rises, the module responds to the highest temperature recorded by any one of the thermistors. In the event of a thermistor failure, the fans will run at full speed for fail safe operation. A shutdown and stand-by mode for low temperatures (T0) is also available which is particularly useful for equipment exposed to very cold ambient temperatures outdoors.
155
System 3000 monitor module System 3000 control module Up to 65W of PAPST DC fans or blowers Terminal connections
thermistor fail
38 63 M3.5 hole ­ 4 places
· Low temperature fan shutdown/ standby mode · Fail safe operation for thermistor fail · Operates as a stand-alone controller or can be combined with System 3000 Monitor Module. · All I/O connections are via screw terminals · Protection: reverse polarity and power
175 165 50
Relay
LED or open collector
1 2
3 4
5 6
7 8
9
31 32
Alarm outputs
Ordering Information Part No. S3000-C12 S3000-C24 S3000-C48 Description PAPST System 3000 Switch Mode Control Module 12VDC PAPST System 3000 Switch Mode Control Module 24VDC PAPST System 3000 Switch Mode Control Module 48VDC
limiting on 5V supply · Operating temperature range: 0 - 70°C · EMC compliance to EN50081-1:1992; EN61000-4-3:1996 & EN61000-4-2:1995.
All measurements in mm.
Papst plc East Portway Andover Hampshire SP10 3RT Tel +44 (0)1264 333388 Fax +44 (0)1264 332182 www.papstplc.com
Fit it. Forget it.
thermal management systems
system 3000 monitor module
Description The system 3000 is a comprehensive solution for the control and monitoring of PAPST DC fans, together providing a thermal management system for electronic equipment. It offers a modular approach enabling the Monitor Module to function as a separate monitoring unit or as a complete system integrated with the Control Module.
Alarm Functions and Outputs One set of single pole change-over volt-free contacts provide an alarm indication should any fan fall below the selected speed threshold. Each of the six fans has a corresponding open collector alarm output. Each output will become independently active if the speed of its related fan falls below the selected threshold. These outputs can be used to drive LED's if required in conjunction with the 5VDC integral logic supply. Features
· Individual fan alarm output · Supports 12, 24 or 48VDC PAPST fans · Several fan fail threshold settings available · Easy to integrate and connect to equipment · Operates as a stand-alone monitor or can be combined with System 3000 Control Module. · All I/O connections are via screw terminals · Protection: reverse polarity and power limiting on 5V supply · Operating temperature range 0 to 70°C · EMC compliance to EN50081-1:1992; EN61000-4-3:1996 & EN61000-4-2:1995
Fan Monitoring The unit provides `fan failing' monitoring for up to 6 PAPST DC fans or blowers fitted with open collector (/ 2) or TTL (/12) sense wires. If the speed of any fan falls below one of the user selectable thresholds an alarm will be triggered.
The System 3000 Monitor Module offers advanced monitoring for thermal management systems providing: · Monitoring for up to 6 PAPST DC fans or blowers · Alarm outputs for direct or remote fan status
155
System 3000 control module Up to 6 PAPST DC fans or blowers Terminal connections
38 63
175 165
System 3000 monitor module
50
Relay LED or open collector
M3.5 hole ­ 4 places
2 1 4 3 6 5 8 7 31 32
Alarm outputs
Ordering Information Part No. S3000-M12 S3000-M24-48 Description PAPST System 3000 Monitor Module 12VDC PAPST System 3000 Monitor Module 24-48VDC
All measurements in mm.
Papst plc East Portway Andover Hampshire SP10 3RT Tel +44 (0)1264 333388 Fax +44 (0)1264 332182 www.papstplc.com
Fit it. Forget it.
system 5000 integrated control and monitoring
Description The System 5000 has been developed with the critical thermal needs of the equipment designer in mind. It allows for maximum control of the thermal profile required by today 's sophisticated electronic equipment while introducing an `environmentally friendly' aspect to the design. Speed Control Temperature dependent speed control is provided for up to 6 PAPST DC fans or blowers with a combined power rating governed by the power module. The control module makes use of up to 8 thermistors which can be located remotely with the equipment in the areas deemed to be the most sensitive. The control module can regulate the fan speed linearly between half and full speed. This is achieved by two customer defined temperature settings, T1 (lower level) and T2 (upper level). As the surrounding ambient temperature rises, the system reacts to the highest temperature recorded by any one of the thermistors. In the event of a thermistor failure, the system can be programmed to run fans at full speed for fail safe operation. A shutdown and stand-by mode for low temperatures can also be programmed to a user defined setting T0, particularly useful for equipment exposed to very cold ambient temperatures.
Fan speed is fully controlled and regulated by the functionality of the power module. If the input voltage fluctuates, for example due to power fail or charge mode in a battery backup system, the fans will continue to operate in their temperature controlled state. Expandability With additional programming, up to an extra 8 fans can be monitored (expansion module) or heater/chillers can be switched on within the customers' system (power switching module). Fan Monitoring The System 5000 can be used in conjunction with PAPST DC fans fitted with open collector (/ 2) or TTL (/12) sense wires for fan monitoring. The module will provide `fan failing' monitoring for up to 6 PAPST DC fans or blowers. If the speed of any fan falls below a pre-programmed percentage of the nominal speed, an alarm is triggered.
Alarm Functions Four uncommitted alarm outputs are available. Typical configurations include: I. Upper temperature T2 reached II. Over temperature alarm T3 should the ambient temperature continue to rise above T2 III. Fan failing IV. Thermistor fail Features The System 5000 offers a modular approach to environmental control providing: · Temperature dependant speed control · Multiple point temperature sensing · Regulated output allowing independent control of fan speed over a wide input voltage · Fan fail monitoring · Fully programmable functionality · Fail safe operation · Four uncommitted alarm outputs that can be assigned to suit customer requirements · Variety of expansion modules for additional functionality · Individually programmed to customer requirements.
Front panel display 50 Watt power module Output relay board 150 Watt power module 4 alarm outputs
Reset
Up to 6 fans or blowers
Control module
Expan. board
Power switch board
Up to 8 thermistors
TTL output board
Note dotted lines show expansion options.
Papst plc East Portway Andover Hampshire SP10 3RT Tel +44 (0)1264 333388 Fax +44 (0)1264 332182 www.papstplc.com