Part: DCXL30DN
Category: Sensors -> Pressure Sensors
Description: Pressure Sensor
Company:
Datasheet: Download DCXL30DN datasheet File size : 122 kB
Request For quote: Find where to buy DCXL30DN
Datasheet text preview:
OCTOBER 1997
SURSENSETM Ultra Low Pressure Sensors
DCXL Series
Millivolt Output High Accuracy Compensation Full Scale Pressure Ranges 0 to 1 in. H2O to 0 to 30 in. H 2O
DESCRIPTION
The SURSENSETM line of ultra low pressure sensors is based upon a proprietary, patent applied for technology designed to reduce all output offset or common mode errors. These sensors utilize a silicon, micromachined sensing element which features a unique stress concentration enhanced structure to provide a highly stable linear output that is proportional to applied pressure. Output of fset errors due to changes in temperature, warm-up, long term stability and position sensitivity have all been significantly reduced when compared to conventional sensors. The DCXL series sensors provide a precision calibrated ratiometric millivolt output with SURSENSE enhanced stability. Each sensor features calibrated offset, fullscale span and thermal error calibration to ensure the highest possible accuracy for flow pressure measurement. These highly stable sensors feature an industry standard ported package with improved stress isolation for printed circuit board mount applications.
APPLICATIONS
s Medical Instrumentation s HVAC s Industrial Instrumentation s Environmental Controls
FEATURES
s Available in Gage and Differential Pressure Ranges s Temperature Compensated over 0°C to 50°C s Position Sensitivity to ±5µV/g s Warm-up drift < ±50µV s Long Term Stability < ±100µV s Combined Linearity and Hysteresis Error < ±0.25% s Custom Calibration Available
EQUIVALENT CIRCUIT
+VSUPPLY (2)
PINOUT 1 2 3 N/C +VSUPPLY +VOUTPUT VSUPPLY VOUTPUT N/C
VOUTPUT (5)
VOUTPUT (3)
4 5
VSUPPLY (4)
6
+
DCXL Series
SURSENSETM Ultra Low Pressure Sensors
DCXL01DN
Millivolt Output High Accuracy Compensation 1 in. H2O Full Scale Pressure MAXIMUM RATINGS
PARAMETER MINIMUM MAXIMUM UNITS
Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Excitation Voltage Common Mode Pressure Humidity Limits
25 40 100 200
85 125
°C °C in. H2O in. H2O
16 50 0 100
V psig %RH
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS
Operating Pressure Range Output Span, (1.0 in. H2Ooffset) Offset Voltage Temperature Effect on Offset (0°C50°C), note 2 Temperature Effect on Span (0°C50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 4 Input Resistance Output Resistance Common Mode Voltage, % excitation 9.0
1.0 10.0 11.0 ± 500 ± 250 ± 200 ± 100 ± 50 ± 200 0.05 4.5 1.5 50 0.25
in. H2O mV µV µV µV µV µV µV %FS K K %
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 12V DC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: Shift is relative to 25°C. Note 3: Shift is within the first hour of excitation applied to the device. Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
DCXL Series
SURSENSETM Ultra Low Pressure Sensors
DCXL05DN
Millivolt Output High Accuracy Compensation 5 in. H2O Full Scale Pressure MAXIMUM RATINGS
PARAMETER MINIMUM MAXIMUM UNITS
Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Excitation Voltage Common Mode Pressure Humidity Limits
25 40 150 300
85 125
°C °C in. H2O in. H2O
16 50 0 100
V psig %RH
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS
Operating Pressure Range Output Span, (1.0 in. H2Ooffset) Offset Voltage Temperature Effect on Offset (0°C50°C), note 2 Temperature Effect on Span (0°C50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 4 Input Resistance Output Resistance Common Mode Voltage, % excitation 19.0
5.0 20.0 21.0 ± 500 +45 +125 ± 150 ± 200 ± 50 ± 10 ± 100 0.05 10 1.5 50 ± 0.25
in. H2O mV µV µV µV µV µV µV %FS K K %
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 12VDC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: Shift is relative to 25°C. Note 3: Shift is within the first hour of excitation applied to the device. Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
DCXL Series
SURSENSETM Ultra Low Pressure Sensors
DCXL10DN
Millivolt Output High Accuracy Compensation 10 in. H2O Full Scale Pressure MAXIMUM RATINGS
PARAMETER MINIMUM MAXIMUM UNITS
Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Excitation Voltage Common Mode Pressure Humidity Limits
25 40 150 300
85 125
°C °C in. H2O in. H2O
16 50 0 100
V psig %RH
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS
Operating Pressure Range Output Span, (1.0 in. H2Ooffset) Offset Voltage Temperature Effect on Offset (0°C70°C), note 2 Temperature Effect on Span (0°C70°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 4 Input Resistance Output Resistance Common Mode Voltage, % excitation 19.0
10.0 20.0 21.0 ± 500 +45 ± 150 ± 150 ± 50 ± 10 ± 100 0.05 13 1.5 50 0.25
in. H2O mV µV µV µV µV µV µV %FS K K %
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 12V DC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: Shift is relative to 25°C. Note 3: Shift is within the first hour of excitation applied to the device. Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
DCXL Series
SURSENSETM Ultra Low Pressure Sensors
DCXL20DN
Millivolt Output High Accuracy Compensation 20 in. H2O Full Scale Pressure MAXIMUM RATINGS
PARAMETER MINIMUM MAXIMUM UNITS
Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Excitation Voltage Common Mode Pressure Humidity Limits
25 40 300 450
85 125
°C °C in. H2O in. H2O
16 50 0 100
V psig %RH
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS
Operating Pressure Range Output Span, (1.0 in. H2Ooffset) Offset Voltage Temperature Effect on Offset (0°C70°C), note 2 Temperature Effect on Span (0°C70°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 4 Input Resistance Output Resistance Common Mode Voltage, % excitation 19.0
20.0 20.0 21.0 ± 500 ± 150 ± 150 ± 50 ±5 ± 100 0.01 10 2 50 0.25
in. H2O mV µV µV µV µV µV µV %FS K K %
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 12VDC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: Shift is relative to 25°C. Note 3: Shift is within the first hour of excitation applied to the device. Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.