Datasheet text preview:
w11_1we Seite 3 Montag, Juli 29, 1996 1:08 PM

Small Relay W11 1 changeover contact

V23101

PCB relay for DC operation, non-polarized, monostable
Features
q q q

General-application relay Small size permitting high packing density High vibration resistance (10 to 38 Hz: 3.3 mm double amplitude 38 to 200 Hz: 10 g) High shock resistance 30 g for sensitive and standard version Sensitive version usable up to an ambient temperature of 85 °C
ECR0987-Y Approx. 1.5 x original size

q

q

Typical applications
q q q q

Version
­ Monostable, 1 winding or bistable, 1 winding, on request Terminal assignments symmetrical or asymmetrical and 5- or 6-pin version For 1 A or 3 A continuous current Standard or sensitive For printed circuit assembling Plastic case Immersion cleanable

Security devices Electric door openers Duplex intercommunication systems Measurement and control

­

­ ­ ­ ­ ­

Siemens AG

3

w11_1we Seite 4 Montag, Juli 29, 1996 1:08 PM

Small Relay W11 1 changeover contact

Dimension drawing (in mm)

Mounting hole layout
View on the terminals Version: 6 pins Version: 5 pins (without pin no. 6)

Basic grid 2.54 mm according to EN 60097 and DIN 40803, average

Terminal assignment
View on the terminals Terminal assignment A symmetrical Version: 6 pins Terminal assignment B asymmetrical Version: 6 pins

Version: 5 Pins

Version: 5 Pins

4

Siemens AG

w11_1we Seite 5 Montag, Juli 29, 1996 1:08 PM

Small Relay W11 1 changeover contact

Contact data
Ordering code block 3 Contact material Max. continuous current at max. ambient temperature Maximum switching voltage Maximum switching capacity DC voltage *) AC voltage Recommended for load voltages greater than Contact resistance (initial value) / measuring current / driver voltage
*)

A201 or B201 AgPd, gold-plated 1A 60 V­ 125 V~ 30 W 60 VA 1V 100 m / 10 mA / 20 mV

A301 or B301 AgNi 10 3A

72 W 360 VA 5V 100 m / 100 mA / 6 V

see also load limit curve

Load limit curve

I = switching current U = switching voltage = recommended application field
Load limit curve: Quenching of the arc before the transit time

Siemens AG

5

w11_1we Seite 6 Montag, Juli 29, 1996 1:08 PM

Small Relay W11 1 changeover contact

Coil data
Nominal voltages Typical nominal power consumption standard version sensitive version Operative range/pickup class according to IEC 255-1-00 and VDE 0435 Part 201 Maximum operating voltage standard version sensitive version Minimum release voltage From 5 V­ to 24 V­ 450 mW 200 mW 1/a

70% of the nominal voltage 75% of the nominal voltage 10% of the nominal voltage

UI UII

= Minimum voltage at 20 °C after pre-energizing with nominal voltage without contact current = Maximum continuous voltage at 20 °C

The operating voltage limits UI and UII are dependent on the temperature according to the formulae:

UI tamb = kI · UI 20 °C and UII tamb = kII · UII 20 °C tamb = UI tamb = UII tamb= kI a. kII =
Ambient temperature Minimum voltage at ambient temperature, tamb Maximum voltage at ambient temperature, tamb Factors (temperature dependent), see diagram

Ambient temperature, tamb [°C]

6

Siemens AG

w11_1we Seite 7 Montag, Juli 29, 1996 1:08 PM

Small Relay W11 1 changeover contact

Coil versions
Nominal voltage Unom V­ Standard version 1.5 3 5 6 9 12 24 Sensitive version 1.5 3 5 6 9 12 24 1.13 2.25 3.75 4.5 6.75 9.0 18.0 3.6 7.1 11.6 14.2 21.2 28.0 56.0 12 ± 45 ± 120 ± 180 ± 400 ± 700 ± 2800 ± 1.2 4.5 12 18 40 70 280 101 102 103 104 105 106 107 1.25 2.1 3.5 4.2 6.3 8.4 16.8 2.6 4.7 7.9 9.5 14.2 19.0 38.0 6± 20 ± 56 ± 80 ± 180 ± 320 ± 1280 ± 0.6 2 5.6 8 18 32 128 001 002 003 004 005 006 007 Operating voltage range at 20 °C Minimum voltage, UI V­ Maximum voltage, UII V­ Resistance at 20 °C Coil number Ordering code block 2

Siemens AG

7




Others parts begin by 00