Miniature Power Relay IF - Faston

V23077

PCB/plug-in relay for DC voltage, neutral, monostable
Features
q

High-temperature relay with contact-side Faston terminals Switching capacity 4000 VA at 125 °C ambient temperature Nominal coil power 360 mW Mechanical and electrical characteristics comply with the "Rules for electrical relays in power installations" (VDE 0435/9.72) Clearance/creepage distances > 8 mm between coil and contact Tracking resistance of the plastics to PTI 250 Used for safe electrical insulation in the following applications ­ open and closed-loop control equipment for domestic use (VDE 0631) ­ electrical equipment for domestic use (EN 60 335-1/VDE 0700)
ECR3029-2 Approx. original size

q

q q

q

q q

Design
­ With 1 make contact or with 1 break contact (changeover contact on request) For printed circuit assembling With PCB terminals (coil) and flat terminals (contacts) for 6.35 mm fast-on connectors Dust-protected

­ ­

Typical applications
q q q q q

­

Oven timers Electric heaters Microwave ovens Air-conditioning equipment Power supply equipment SEV CSA UL SEMKO ÖVE
BEAB

Approvals
VDE

VDE

Mark of conformity 91.1 11672.01 LR 89731-12 File E 48393 9330076 22905/E C 0573

5081

BEAB

2

Siemens AG

Miniature Power Relay IF - Faston

Dimensional drawing (in mm)

F a st -on c onnectors

Mounting hole layout
View on the terminals

Note
The dust-protected version must be checked to ensure that the clearances and creepage distances required by VDE are not compromised by conductor paths running between the relay and the board.

2.5 mm basic grid to EN 60097 and DIN 40803, fine

Terminal assignment
View on the terminals

1 make contact

1 break contact

Siemens AG

3

Miniature Power Relay IF - Faston

Contact data
Contact category III according to VDE 0435 Part 120/10.81, Appendix B Ordering code, block 3 Number of contacts and type Contact assembly Contact material Max. continuous current at max. ambient temperature Inrush current (max. 4 s for 10% duty cycle) Maximum switching voltage Maximum switching capacity AC voltage DC voltage Recommended for loads greater than Contact resistance (initial value)/ measuring current/driver voltage Note: Inrush currents up to 150 A available on request. 16 A 25 A 440 V~ 300 V­ 4000 VA See load limit curve 500 mA, 12 V~ 100 m/1 A/24 V A402 1 make contact Single contacts AgCdO (AgSnO2 on request) 16 A 25 A A403 1 break contact

Load limit curve

I = switching current U = switching voltage = recommended application field
Load limit curve: Safe switch-off, no stationary arc > 10 ms

4

Siemens AG

Miniature Power Relay IF - Faston

Coil data
Nominal voltages Nominal power consumption, typ., at 20 °C Pull-in power, typ., at 20 °C Operating range/pickup class according to IEC 255-1-00 and VDE 0435 Part 201 Minimum release voltage From 3 V­ to 110 V­ 360 mW 140 mW 2/b 10 % of nominal voltage

Coil versions
Nominal voltage

Unom V­
3 6 12 24 48 60 110

Operate voltage at 20 °C Uop cold V­ 1.9 3.8 7.5 14.9 30.0 37.2 68.2

Operating voltage range at 20 °C Min. voltage UI V­ 2.1 4.2 8.4 16.8 33.6 42.0 77.0 Max. voltage UII V­ 8.5 16.9 33.8 67.7 135.3 169.1 310.1

Resistance at 20 °C 25 ± 100 ± 400 ± 1600 ± 6400 ± 10000 ± 33610 ± 2.5 10 40 160 640 1000 3360

Coil number Ordering code block 2 001 003 005 007 009 010 012

Other coil versions available on request

Uop cold= Operate voltage at 20 °C without pre-energizing the coil UI UII
= Minimum voltage at 20 °C after pre-energizing with Unom without contact current = Maximum continuous voltage at 20 °C for Tc max = 115 °C without contact loading kII kI

Unom = Nominal voltage
Operating voltage limits UI and UII depend on temperature and can be calculated by:

UI tamb = kI · UI 20 °C and UII tamb= kII · UII 20 °C tamb = UI tamb = UII tamb= kI a. kII = Tc max =
Ambient temperature Minimum voltage at ambient temperature tamb Maximum voltage at ambient temperature tamb Factors (dependent on temperature), see diagram Maximum coil temperature

Ambient temperature tamb

Siemens AG

5

Miniature Power Relay IF - Faston

General data
Operate time at Unom and 20 °C, typ. Release time without/with diode in parallel, typ. Bounce time, make/break contact, typ. Maximum switching rate without load Maximum switching rate with rated load Ambient temperature range according to IEC 255 Part 1-00 or VDE 0435 Part 201 Thermal resistance Maximum permissible coil temperature Degree of protection according to IEC 529/ VDE 0470 Part 1 Electrical endurance Mechanical endurance Flammability according to UL 94 Solder bath temperature/max. duration Mounting position Weight (mass) 10 ms 2 ms / 14 ms 1/2 ms 1200 min-1 10 min-1 -40 °C ... +125 °C 65 K/W 155 °C dust-protected IP 54 1 x 105 operations 3 x 107 operations V-0 260 °C / 5 s any approx. 26 g

Insulation
According to IEC 664/VDE 110 (1/89): rated voltage pollution severity overvoltage category According to VDE 0110 (2/79): insulation group/rated voltage Dielectric test voltage (1 min): contact/coil between open contacts Clearances/creepage distances Tracking resistance of the fundamental frame according to IEC 112 250 V 3 III C/250 B/380 4000 V~rms 1000 V~rms 8 mm / 8 mm PTI 250

6

Siemens AG