Solid State Relays (SSR)
V23100-S V23107-S
Features
q q q
Design
With or without zero voltage switch One- and three-phase relay types Switching circuit: triac or 2 anti-parallel thyristors; corresponds to one make contact Terminal type: PCB and screw Plastic coating Dust-protected (V23100-S... Type C2) or immersion cleanable
Fully electronic semi-conductor relays High switching speed and endurance Switch-on at voltage zero crossing, with relays with zero voltage switch Switch-off in current zero crossing Silent switching Spark- and bounce-free switching Electrical isolation between control circuit and switching circuit Low control power Logic compatibility (TTL) Not sensitive to vibration, impact or extreme environmental conditions
q q q q
q q q
Typical applications
q q q q q q q
Heating control systems Ovens and cookers Photocopying machines High performance laser printers Medical equipment Industrial controls Traffic signaling systems
Approvals
VDE Marks of conformity
7 9102
VDE
and
867 13
UL
ML File E 85134 and ML File E48393
Siemens AG
9
Solid State Relays (SSR) Type B404
Dimension drawing (mm)
ECR0980-B
Illustration approximately same size as original
Tolerances
Mounting hole layout
View on the terminals
Basic grid dimension 2.54 mm in accordance with EN 60097
Terminal assignment
Simplified circuit diagram
10
Siemens AG
Solid State Relays (SSR) Type B404
SSR with zero voltage switch for PCB mounting Ordering code
V23107 -S4022-B404 -S4023-B404 -S4042-B404 -S4043-B404
Control circuit (typical values at 20 °C)
Minimum control voltage Maximum control voltage Minimum control current Maximum control current Release voltage Control circuit resistance 330 4 Arms 5 mArms 230 Vrms 12...275 Vrms 600 VS (450 VS) 400 Vrms 12...460 Vrms 1,000 VS (720 VS)
±12
2.5 V- 10 V- 3 mA- 30 mA- 0.8 V-
4 V- 30 V-
1,000
Switching circuit (typical values at 20 °C)
Maximum switching current (see characteristic page 13) Minimum switching current Nominal switching voltage Switching voltage range Maximum repetitive blocking voltage (Voltage limited by varistor) Zero voltage range Maximum surge current (ITSM, 10 ms) (see surge current gradient page 13) Leakage current at nominal switching voltage (50 Hz) Peak load integral (I2t, 10 ms) Critical rate of rise on-state current (di/dt) Critical rate of rise off-state voltage (du/dt) Max. on-state voltage at max. switching current Operating frequency range Maximum on- and off-time (50 Hz)
230 Vrms 12...275 Vrms 600 VS (450 VS) VS 100 AS
400 Vrms 12...460 Vrms 1,000 VS (720 VS)
0.3 mArms 50 A2s 20 A/µs 500 V/µs 1.6 VS 10...440 Hz 10 ms
Insulation
Test voltage between control circuit and switching circuit 4 kVrms
General data
Operating temperature range Storage temperature range Capacity between control circuit and switching circuit Weight Approvals -40...+80 °C -40...+150 °C 8 pF approx. 20 g VDE, UL
N.B.: Clearances and creepage distances in accordance with EN 60950:1992+A1/DIN EN 60950 (VDE 0805):11.93
Siemens AG
11
Solid State Relays (SSR) Type B404
SSR without zero voltage switch for PCB mounting Ordering code
V23107 -S4342-B404 -S4343-B404
Control circuit (typical values at 20 °C)
Minimum control voltage Maximum control voltage Minimum control current Maximum control current Release voltage Control circuit resistance 3 V- 30 V- 2 mA- 30 mA- 0.8 V- 1,000 4 Arms 5 mArms 230 Vrms 12...275 Vrms 600 VS (450 VS) 100 AS 0.3 mArms 50 A2s 20 A/µs 500 V/µs 1.6 VS 10...440 Hz 0.1 ms 10 ms 400 Vrms 12...460 Vrms 1,000 VS (720 VS)
Switching circuit (typical values at 20 °C)
Max. switching current (see characteristic page 13) Minimum switching current Nominal switching voltage Switching voltage range Maximum repetitive blocking voltage (voltage limited by varistor) Maximum surge current (ITSM, 10 ms) (see surge current gradient page 13) Leakage current at nominal switching voltage (50 Hz) Peak load integral (I2t, 10 ms) Critical rate of rise on-state current (di/dt) Critical rate of rise off-state voltage (du/dt) Max. on-state voltage at max. switching current Operating frequency range Maximum on time Maximum off time
Insulation
Test voltage between control circuit and switching circuit 4 kVrms
General data
Operating temperature range Storage temperature range Capacity between control circuit and switching circuit Weight Approvals -40...+80 °C -40...+150 °C 8 pF approx. 20 g VDE, UL
N.B.: Clearances and creepage distances in accordance with EN 60950:1992+A1/DIN EN 60950 (VDE 0805):11.93
12
Siemens AG
Solid State Relays (SSR) Type B404
Maximum accidental overload current (not periodical): ITSM
Surge current [A]
Number of periods
Max. switching current depending on ambient temperature
Switching current [Arms]
Control voltage < 10 V
Control voltage > 10 V
Ambient temperature [°C]
Siemens AG
13
Others parts begin by 00